sigma_z error

Use of Cobaya. camb, CLASS, cosmomc, compilers, etc.
Post Reply
Ruth Lazkoz
Posts: 14
Joined: January 02 2006
Affiliation: University of the Basque Country

sigma_z error

Post by Ruth Lazkoz » March 22 2010

Hi,

We have explored the guts of the survey specifications for bao and for thee
default one (Euclid) it seems to be set at 0.00, should it not be 0.001?

Thanks,

Ruth

Anais Rassat
Posts: 24
Joined: October 20 2004
Affiliation: LASTRO (EPFL)
Contact:

sigma_z error

Post by Anais Rassat » March 31 2010

Dear Ruth,

Indeed, the requirement for the Euclid spectroscopic survey is \sigma_z< 0.001(1+z) (see http://arxiv.org/abs/0912.0914).

Thanks for your post. Anais.

Post Reply